Super Mushroom Powerup is an injection molded toy based on the mushroom from the Mario games, made for ME 340-2 at Northwestern. Over ten weeks, our team of four designed the part, designed its aluminum molds in Siemens NX, machined them on a Haas Super Mini Mill, and molded a production run on Morgan Press machines.
The body is a hollow shell split into two halves that press together on three interference-fit pins. Four spots press into holes on the cap, so they can be molded in a different color without multi-shot molding, paint, screws or glue. A metrology study on the finished parts closed out the project.
PART DESIGN
The body splits along a plane that follows the rim of the dome, oriented so neither half has an undercut and each can be molded in a simple two-part tool. The form started as sketches for proportion, then moved into NX as spline-defined surfaces for smooth curvature control.
The halves join on three internal pin-and-hole features sized for an interference fit. Each spot’s inner face follows the local curvature of the cap, so it sits flush and keeps full contact. Walls hold a nominal 0.075 in to cool evenly and avoid sink and warp, growing to about 0.125 in around the assembly columns to leave room for the 1/8 in cutter that forms them.





MOLD DESIGN
The body parting line runs through the center of the spot holes, which removes every overhang and side pull. The spots are thin enough that both of their mold halves are cavities. Every sharp edge has a fillet to manage shrink and warp, and the spots mold includes a cold slug well to catch the cold front of the melt.
Gates sit at the thickest wall. For the body that is the center of the base, so each cavity fills fully and symmetrically. Runners to every cavity are the same length to balance flow and prevent short shots and flash.


MOLD MACHINING
We programmed the toolpaths in NX CAM and cut all four mold halves on a Haas Super Mini Mill in the Ford Design Shop. Each half went from roughing through floor facing, planar, cavity and area milling finishes, stepping down from a 1/2 in end mill to a 1/16 in ball mill for the tightest contours. The body core alone took 2.5 to 3 hours of cutting.
Changing the cut patterns on the spots cavity finish brought its projected time from 2 hours 7 minutes down to about 1 hour 33 minutes. A misplaced CAM axis on the body core sent the tool away from the blank on the first run. We fixed the axis in NX, reposted and reran.






MOLDING AND METROLOGY
We molded with the nozzle at 450°F and the barrel at 425°F, tuning fill time shot by shot. Flash meant a shorter fill and short shots meant a longer one, and we filed the gates after seeing one side fill faster than the other. Cooling came down from about 10 s to 5 s for the body and 3 s for the spots.
We measured the maximum outer diameter of the dome against a nominal 1.676 in. Mold machining and polypropylene shrink uncertainty combine by root sum square to a tolerance of ±0.007 in. Across 22 parts from each half, both groups averaged slightly under nominal with no trend over the run, and most parts fall within tolerance.




IM MACHINE PLATE DRAWINGS
These sheets document the injection molding machine’s mounting plates, the shop hardware our molds bolt into.
01 / 04
02 / 04
03 / 04
04 / 04